Panel is running on battery power only or AC power only. No supervision is provided for the notification appliance circuit. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch.
#Silent knight 5700 default installer code code#
Add to Cart The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. Sale 118.74 Regular price 189.98 Quantity. Panel is running on AC (normal condition) standby battery fully charged. Silent Knight SK-RELAY Addressable Relay Module. LED will flash when a trouble condition exists that has not been acknowledged.Īlarm or trouble condition has been silenced but condition still exists. LED will flash when a supervisory condition exists that has not been acknowledged. If a supervisory condition exist on the system. LED will flash when a alarm condition exists that has not been acknowledged. Acknowledged events in the history buffer will be preceded with an asterisk “*”. Supervisories and troubles will silence once the event is restored.Īfter the event is acknowledged an event is added to the event history buffer. The 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote. Note: The control panel piezo will continue to sound for Supervisories and Troubles even after the event has been acknowledged. The Silent Knight 5700 is a class leading single loop addressable fire alarm control/communicator system and is also equipped with such features as drift compensation and maintenance alert.

The control panel piezo will silence after all alarms have been acknowledged. When viewing system status the LCD displays “Acked” for each individual event once it has been acknowledged. The status LEDs (Alarm, Supervisory and Trouble) will flash when an un-acknowledged alarm, supervisory, or trouble condition exists.Īfter each event has been acknowledged its associated LED (Alarm, Supervisory, or Trouble LED) stop flashing and turn onĪcknowledge Events steady. No code is required to acknowledge events. List Alarms first,Įvents can be acknowledged by pressing the button. Supervisories, troubles, reports, time and date changes, etc. Resets the dialer and aborts the call to central station.ĭisplays the panel history, which includes alarms, Clear History 2 ENTER Clear History Enter Code Enter Installer Code Clears event history of all events.

Reset Alarms 1 ENTER or RESET Reset Alarm Enter Code Enter Code Resets system. The system will perform a display lamp test and a Enter Code Enter Code System performs a display lamp test, a communication test, and displays the firmware number and revision. These instructions must be framed and displayed next to the panel in accordance with NFPA 72 fire code for Local Fire Alarm System. If all this fails, as in my case, you will have to mail the unit back to the dealer (or someone like the above post) and for a fee have them reset your User Code back to 1111. SK-5208 Basic Operating Instructions P/N 151214 Rev. A Visonic tech can call into the unit and reset your User Code and/or Installer Code if your unit is hooked into a phone line and the Remote Access setting is set to ON.